RBR71S221R0BP
Resistor Fixed Wire Wound Nonind
Description
Procurement notes for RBR71S221R0BP.
Resistor Fixed Wire Wound Nonind ASAP can support availability checks, alternate review, lead-time confirmation, and documentation requirements tied to the part number, NSN, CAGE code, or active bill of materials.
Catalog classifications
NSN Information for Part Number RBR71S221R0BP with NSN 5905-00-048-7128, 5905000487128
Characteristics Data of NSN 5905-00-048-7128, 5905000487128
| MRC | Criteria | Characteristic |
|---|---|---|
| AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -10.0/+10.0" |
| AAPP | ELECTRICAL RESISTANCE | 221.000 OHMS" |
| AAPQ | RESISTANCE TOLERANCE IN PERCENT | -0.100/+0.100" |
| AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0" |
| AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 145.0" |
| AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -65.0 TO 145.0" |
| AAQZ | INCLOSURE METHOD | ENCAPSULATED" |
| AARB | TERMINAL TYPE | WIRE LEAD" |
| AARG | RELIABILITY INDICATOR | ESTABLISHED" |
| AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010" |
| ABPM | BODY DIAMETER | 0.250 INCHES NOMINAL" |
| ADAQ | BODY LENGTH | 0.312 INCHES NOMINAL" |
| AEFB | POWER DISSIPATION RATING IN WATTS | 0.125 FREE AIR" |
| STYL | STYLE DESIGNATOR | AXIAL TERMINALS ONE END" |
| TEST | TEST DATA DOCUMENT | 81349-MIL-R-39005 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI" |
| AAPE | TEMP COEFFICIENT OF RESISTANCE IN PPM PER DEG CELSIUS | -10.0/+10.0" |
| AAPP | ELECTRICAL RESISTANCE | 221.000 OHMS" |
| AAPQ | RESISTANCE TOLERANCE IN PERCENT | -0.100/+0.100" |
| AAQF | AMBIENT TEMP IN DEG CELSIUS AT FULL RATED POWER | 125.0" |
| AAQG | AMBIENT TEMP IN DEG CELSIUS AT ZERO PERCENT RATED POWER | 145.0" |
| AAQH | TEMP RANGE OF TEMP COEFFICIENT IN DEG CELSIUS | -65.0 TO 145.0" |
| AAQZ | INCLOSURE METHOD | ENCAPSULATED" |
| AARB | TERMINAL TYPE | WIRE LEAD" |
| AARG | RELIABILITY INDICATOR | ESTABLISHED" |
| AARH | RELIABILITY FAILURE RATE LEVEL IN PERCENT | 0.010" |
| ABPM | BODY DIAMETER | 0.250 INCHES NOMINAL" |
| ADAQ | BODY LENGTH | 0.312 INCHES NOMINAL" |
| AEFB | POWER DISSIPATION RATING IN WATTS | 0.125 FREE AIR" |
| STYL | STYLE DESIGNATOR | AXIAL TERMINALS ONE END" |
| TEST | TEST DATA DOCUMENT | 81349-MIL-R-39005 SPECIFICATION (INCLUDES ENGINEERING TYPE BULLETINS, BROCHURES,ETC., THAT REFLECT SPECIFICATION TYPE DATA IN SPECIFICATION FORMAT; EXCLUDES COMMERCIAL CATALOGS, INDUSTRY DIRECTORIES, AND SIMILAR TRADE PUBLICATIONS, REFLECTI" |
