Part detail

10402

Resistor Variable W

Request a quote

Pricing in 15 minutes.

Part number10402
Description

Procurement notes for 10402.

Resistor Variable W ASAP can support availability checks, alternate review, lead-time confirmation, and documentation requirements tied to the part number, NSN, CAGE code, or active bill of materials.

Catalog classifications

NSN Information for Part Number 10402 with NSN 5905-00-974-6426, 5905009746426

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5905009746426

Item Description:

Resistor Variable W

59050097464260NB
CIICHCCESDPMICCriticalityENAC
UBA0
Part NumberISCRNVCRNCCHCCMSDSSADC
10402525

Characteristics Data of NSN 5905-00-974-6426, 5905009746426

MRCCriteriaCharacteristic
AAPNSECTION QUANTITY1
AAQLBODY STYLERECTANGULAR
AARGRELIABILITY INDICATORNOT ESTABLISHED
ABJTTERMINAL LENGTH0.170 INCHES NOMINAL
ABWVSHAFT DIAMETER0.096 INCHES NOMINAL
ABXFSHAFT LENGTH0.130 INCHES NOMINAL
ADAQBODY LENGTH0.750 INCHES NOMINAL
ADATBODY WIDTH0.170 INCHES NOMINAL
ADAUBODY HEIGHT0.310 INCHES NOMINAL
AEDXSHAFT STYLEROUND, SLOTTED
AEFDACTUATOR TYPESINGLE SHAFT
AEFHEFFECTIVE ELECTRICAL ROTATION IN DEG ANGULAR ROTATION7200.0 NOMINAL
AEHTCENTER TO CENTER DISTANCE BETWEEN TERMINALS0.500 INCHES NOMINAL
AGAVIII END ITEM IDENTIFICATIONLHA COMMUNICATIONS. DEEP SUBMERGENCE SYSTEMS PROGRAMS (DSSP). PHOENIX AIR TO AIR (AIM-54) MISSLE. LGM-30 MINUTEMAN MISSLE. ALL-WEATHER ANTI-SHIP HARPOON (AGM-84) MISSLE. MODEL 28 TELETYPE. LANDING CRAFT AIR CUSHION (LCAC). AH-1W ADVANCE ATT
APXHTERMINAL LOCATIONLOWER ADJACENT SIDE TWO ROWS
AXGYMOUNTING METHODTERMINAL
AYQRCENTER TO CENTER DISTANCE BETWEEN TERMINAL ROWS0.100 INCHES NOMINAL
CQCCELECTRICAL RESISTANCE PER SECTION10.0 KILOHMS SINGLE SECTION
CQCKROTARY ACTUATOR TRAVEL IN ANGULAR DEG7200.0 NOMINAL
CQCMCENTER TO CENTER DISTANCE BETWEEN CENTER TERMINAL AND OUTSIDE TERMINAL0.200 INCHES NOMINAL
CQGNAMBIENT TEMP IN DEG CELSIUS PER SECTION AT ZERO PERCENT RATED POWER125.0 SINGLE SECTION
CRFJTEMP COEFFICIENT OF RESISTANCE PER SECTION IN PPM PER DEG CELSIUS-100.0 TO 100.0 SINGLE SECTION
CRGDPOWER DISSIPATION RATING PER SECTION IN WATTS1.0 FREE AIR SINGLE SECTION
CRSSRESISTANCE TOLERANCE PER SECTION IN PERCENT-10.0 TO 10.0 SINGLE SECTION
CRSXACTUATOR TRAVEL CONTROL FEATURECLUTCH
CRTLCRITICALITY CODE JUSTIFICATIONFEAT
CSDHAMBIENT TEMP IN DEG CELSIUS PER SECTION AT FULL RATED POWER40.0 SINGLE SECTION
FEATSPECIAL FEATURESWEAPON SYSTEM ESSENTIAL
TESTTEST DATA DOCUMENT13499-381-0003 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRA
TTQYTERMINAL TYPE AND QUANTITY3 PIN