Browse NSN 5930-01-230-3067 Listing of Switch Thermostatic
It is our pleasure to inform you that part number 020-7040-00, 020-7040-00, 77385-000 listed under NSN 5930-01-230-3067 is now available and ready to ship from Fulfillment By ASAP. This part described as a Switch Thermostatic manufactured by Ranco Management Corp, Ranco Inc, Gaymar Industries Inc. If you’d like a quick quote for NSN 5930-01-230-3067, please fill out the form from below. Are you looking to have it delivered today or tomorrow? We can help! Simply complete the Request For Quote (RFQ) form given below to get started, and we will get back to you within 15 minutes!
Alternative NSN: 5930-01-230-3067 |
Item Name: Switch Thermostatic |
Federal Supply Class (FSC): 5930 Switches |
NIIN: 012303067 |
NCB Code: USA (01) |
Manufacturers: Gaymar Industries Inc , Ranco Inc , Ranco Management Corp |
Part No | Manufacturer | Item Name | QTY | RFQ |
---|---|---|---|---|
020-7040-00 | ranco management corp | switch thermostatic | Avl | RFQ |
020-7040-00 | ranco inc | switch thermostatic | Avl | RFQ |
77385-000 | gaymar industries inc | switch thermostatic | Avl | RFQ |
Characteristics Data of NSN 5930012303067
MRC | Criteria | Characteristic |
---|---|---|
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.219 INCHES NOMINAL |
ABKW | OVERALL HEIGHT | 3.700 INCHES MAXIMUM |
ABMK | OVERALL WIDTH | 2.000 INCHES MAXIMUM |
AEVT | CAPILLARY TUBE LENGTH | 48.0 INCHES NOMINAL |
AFDV | LONGEST VERTICAL DISTANCE BETWEEN MOUNTING CENTERS | 1.750 INCHES NOMINAL |
AKBY | TEMP SENSING ELEMENT TYPE | CAPILLARY TUBE |
CQYJ | MOUNTING FACILITY PATTERN | FOUR POSITION RECTANGULAR |
CSCF | TERMINAL TYPE | SCREW |
CTHF | CONTACT LOAD CURRENT RATING | 24.0 AMPERES MOTOR LOAD SINGLE VOLTAGE |
CTYM | CONTACT ADJUSTMENT RANGE | +0.00 TO 55.00 ACTUATION POINT DEGREES FAHRENHEIT |
CTYX | CONTACT STIMULUS RATING | 12.00 DIFFERENTIAL POINT NOMINAL DEGREES FAHRENHEIT |
MEDA | MEDIA FOR WHICH DESIGNED | LIQUID |
CRLD | NONPILE-UP CONTACT ARRANGEMENT | 1 POLE, SINGLE THROW, NORMALLY OPEN, MOMENTARY ACTION |
AFDS | LONGEST HORIZONTAL DISTANCE BETWEEN MOUNTING CENTERS | 2.500 INCHES NOMINAL |
AXGY | MOUNTING METHOD | UNTHREADED HOLE |
ABHP | OVERALL LENGTH | 3.500 INCHES MAXIMUM |
AGAV | END ITEM IDENTIFICATION | 6530-01-134-3182 THERMOREGULATOR,PATIENT |
CQGB | CONTACT ACTION STIMULUS | INCREASE |
CTYC | CONTACT ADJUSTABILITY | ACTUATION POINT ADJUSTABLE, PRESET AND DEACTUATION POINT ADJUSTABLE, PRESET |
CTYS | CONTACT ADJUSTMENT TYPE | EXTERNAL ACTUATION POINT SHAFT |
CTZB | CONTACT VOLTAGE RATING IN VOLTS | 120.0 AC AT SEA LEVEL SINGLE VOLTAGE |
STYL | STYLE DESIGNATOR | RECTANGULAR |
ZZZP | PURCHASE DESCRIPTION IDENTIFICATION | 30958-77385-000 |
Search More Relevant NSN for 5930-01-230-3067, 5930012303067
Most Discovered NSN Part List